10/21/2019 Cqr Fp2 Installation Manual
Outback FlexPower FP2 GVFX3648. FlexPower Two by Outback Power uses all of the essential overcurrent protective devices (OCPD) and puts them in a compact space.
![]()
The FlexPower Two is ideal for applications with minimal power requirements such as off-grid cabins, homes and back-up power systems. Utilizing a compact design and an easy-to-install mounting bracket, the fully pre-wired and tested FlexPower is designed for a quick installation, saving both time and money with just a few household tools. 2 FlexMax FM80 charge controllers with maximum power point tracking gives you a efficient, safe, multi-stage recharging process that prolongs battery life and assures peak performance from a solar array. Outback FlexPower FP2 GVFX3648 Power Center Model Part Number Output Watts Input Current Voltage DC/AC Type Inverter FP2 GVFX36 7,200 80 Amps 48 / 120 or 240 Off-Grid / Grid Tied 2 - GVFX3648 Includes two inverter/chargers, AC and DC wiring boxes, a MATE3, HUB, and Surge Protector. Equipped with battery and solar array breakers; Input-Output-Bypass Assembly; Additional AC breakers Components carry all of the necessary ETL Certifications SURGE PROTECTION: The Flexpower Surge Protector is designed to protect the FlexPower Two’s sensitive components from excessively high voltages (e.g., electrical storms).
Thermally-fused metal oxide varistors (MOVs) limit (“clamp”) these voltages and transfer the resulting current to a lower-voltage port. The Flexpower surge protector features ACTIVE and ERROR LEDs for the DC, AC IN, and AC OUT circuits. The Surge Protector is located in the FlexPower Two’s AC wiring compartment. OutBack Power’s FlexPower Two System is a superior choice when you need a fully integrated, true sinewave, reliable 240V power system.
What's In The Box. 1 - Pre-built Outback, FLEXpowerTWO, Dual GVFX3648 AC Inverters, 7200W, 60Hz, 120/240VAC Bypass, 24VDC, GFDI, Mate3 Control Module and Display, HUB10, RTS (Remote Temp Sensor), Dual FM80 Charge Controllers, FN-DC FlexNet DC Monitor, SP, FP2 GVFX3648 Outback power systems are built to order. Allow 10 business days to ship. Outback FlexPower FP2 GVFX3648 Pre-wired Power Center 240 Volt AC Outback FlexPower Two Power Centers are solid-state electronic devices that, when sized properly, can be used in nearly every solar and wind energy system that uses batteries. The Power Centers Blue Pacific Solar sells employ the latest in power electronics to regulate the battery charge by controlling the charging voltage and current from a solar panel array. Power Centers regulate the charge of the battery, but also prevent the battery from being over discharged which can damage the battery bank.
Off-grid or grid tied with battery backup, here is how the FlexPower Power System basically works. For a grid tied battery backup, grid power comes into the Outback FlexPower power center. If the backup batteries are fully charged, the power is then passed to the critical load or backup load subpanel inside the home. The FlexPower power system is monitoring the sine wave of the grid, amps and volts. When the FlexPower system detects changes outside the default parameters, it immediately begins to draw power from the backup battery system and pushes it to the critical load subpanel. IMPORTANT SAFETY INSTRUCTIONS: FlexPower Two Power Center.
(OK, here is the scary legal disclaimer.) It is the responsibility of the purchaser to ensure that all products are installed and operated in accordance with local and national building codes as specific by the NEC (National Electric Code), UBC (Uniform Building Code) or IBC (International Building Code) and local utility company policy. This product is designed for indoor or protected compartment installations. DO NOT expose the Outback FlexPower Two to rain, snow, moisture or liquids of any type.
Use insulated tools to reduce the chance of electrical shock or accidental short circuits. Remove all jewelry such as rings, watches, bracelets, etc. When installing the FlexPower Two Power Center or any other electronic gear. Always disconnect the batteries or energy source prior to installation or performing maintenance on the FlexPower Two Power Center inverter. Live power may be present at more than one point since an inverter utilizes both batteries and AC electricity.
Turning off the FlexPower Two Power Center may not reduce that risk. Always verify proper wiring prior to starting the inverter. Do not operate the FlexPower Two Power Center if it has been damaged.
Always read and follow the manufactures installation and operating instructions for the Outback FlexPower FP2 GVFX3648 Pre-wired Power Center prior to installation and operation.
Emergency Door Release - Resettable Call Point (Green) EDR FP2/GR/EDR Fully key resettable red manual fire call point which offers almost all commonly used switch monitoring configurations in the one device. Available in white, yellow and green for use in other applications such as Emergency Door Release. Specification:. External dimensions (mm): 87x87. Surface mounted depth with backbox (mm): 55. Flush mounted depth without backbax (mm): 20.
Monitoring resistors: 470, 680ohm. Blocking diode: IN4001. Microswitch rating: 5A 30vdc.
Activation indicator: Fluorescent yellow indicator in window optional LED. Material: Housing ABS, window polycarbonate. Xport 360 v2 usb driver download free. Complies with: IP-44.
Contents. Hardware Support Legend: Y - Working (y=hack), Y - HAL works, not hooked up to UI/MW/init yet, N - Not working,? - Untested, N/A - N/A on device.
Device released Linux Kernel Display Touch LED Audio NFC Bluetooth GSM WLAN GPS Camera Fingerprint Sensors Keys Vibra Haptics Power Mgmt. RTC alarms USB FM Radio SMS Voice Data Connect Hotspot ALS PS Accel. Vol+/- Home Net. Charge 2015/12 3.4.0 Y Y Y Y N/A Y Y Y Y Y Y Y Y N/A Y Y Y Y Y Y N/A Y Y Y Y Y Y Y Status Items marked with FIX have a known fix and will be included in next release. Jolla Store works. Possibly some issues with proximity sensor during calls. (It is possible to calibrate the proximity sensor in Android, which should fix the issues).
Double tap to wake does not work. (Probably not supported by firmware). Youtube videos crash browser when seeking. Random failure of finding resolutions for secondary camera by camera module detection service during installation or update. To solve the issue remove /etc/droid-cameradetect-module-main.conf and /etc/droid-cameradetect-module-front.conf and run 'systemctl restart droid-cameradetect'. Repeat the previous instruction until both cameras work (configuration is at /etc/dconf/db/vendor.d/jolla-camera-hw.txt and the validity of resolutions for secondary camera can be checked also manually) Requirements for installation.
Opensource OS 18.04 Android from Fairphone. Latest Sailfish OS release:. Computer with fastboot installed for fastboot installation. Installation steps.
Th8320u1008 Installation Manual
If you want to update from an existing release, check the. If instead you want to use Sailfish OS installation zip, all data in Sailfish OS will be removed, so backup everything you might need. Calibrate proximity sensor in Android before installing Sailfish OS. Requires Fairphone Opensource OS 18.04 (or Fairphone OS 18.04), not tested on other releases. Install the required Android version (if not installed already) using fastboot and the steps below.
Only flash system.img and recovery.img. DO NOT flash other partitions. Sailfish OS will have a battery drain, if the device has or in the past has had the whole Android Fairphone OS =1.6.2 or Opensource OS = 16.08 installed. To fix it:.
Download. Extract the files from the zip. Go to the folder you extracted the zip.
Check that the device is detected with fastboot devices. fastboot flash modem./BP/NON-HLOS.bin. Extract filesystem images from Android zip on your computer. Enter fastboot mode on your phone by turning off device, when device is powered down press and hold volume down button and then plug USB cable. Open a terminal on your computer and go to the folder where you extracted the file system images.
The FP3 is a resettable and frangible combination EN54-11 compliant manual call point. This gives the freedom to choose whether you wish to have the convenience of a resettable call point or the false alarm deterrence of a frangible call point. The unique mechanism, designed in the United Kingdom by CQR, allows a single key to test and reset the call point after activation. It has a visible warning flag and a LED to confirm activation.
The FP3, with its modern attractive design, achieves the goal of an economically priced high specification manual call point. Key Features:.
Each box contains both resettable (plastic) and frangible (glass) windows. When used in resettable mode, the plastic element has a positive action replicating the feel of breaking glass.
The plastic element avoids the need to fit glass elements which can be lost or broken. Snap-on front cover making it both attractive, with no visible screws, and easier to install. Two resistance values to ensure compatibility, and selectable with jumpers to minimise installation errors. Optional clear lift up cover available for additional protection. External dimensions: width 85 mm,height 85mm. Surface mounted depth with back box: 55mm. Flush mounted depth without back box: 20mm.
Monitoring resistors: 470Ohm;680Ohm,selectable. Blocking Diode: IN4001 (50v),selectable. Microswitch Rating: 12A 250V. Standards: EN54 - 11. Activation indicator:Window displacement. Fluorescent yellow indicator in window. High visibility 360º LED.
Material: Case ABS plastic. Flush Fitting: European Gang Pattress.
Standard BESA box,centres 60mm. Cable entry: Back box 3 x 20mm (2 Top;1 Bottom).
Comments are closed.
|
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |